{"id":974,"date":"2017-04-18T20:25:25","date_gmt":"2017-04-18T18:25:25","guid":{"rendered":"http:\/\/wibroinstal.pl\/?page_id=974"},"modified":"2017-04-24T18:59:16","modified_gmt":"2017-04-24T16:59:16","slug":"montaz-wibroizolatorow-plytowych-typu-b","status":"publish","type":"page","link":"http:\/\/wibroinstal.pl\/en\/montaz-wibroizolatorow-plytowych-typu-b\/","title":{"rendered":"B type plate Vibration Isolators installation"},"content":{"rendered":"\r\n\t<div id=\"fws_69e0f6776a5fc\" data-bg-mobile-hidden=\"\" class=\"wpb_row vc_row-fluid vc_row standard_section   \"  style=\"padding-top: 0px; padding-bottom: 0px; \"><div class=\"row-bg-wrap\"> <div class=\"row-bg   \" style=\"\"><\/div> <\/div><div class=\"col span_12 dark \">\n\t<div  class=\"vc_col-sm-12 wpb_column column_container col no-extra-padding\"  data-padding-pos=\"all\" data-hover-bg=\"\" data-animation=\"\" data-delay=\"0\">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t\n\t<div class=\"wpb_raw_code wpb_content_element wpb_raw_html\">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div>\n\t<div style=\"text-align: center;\"><h2 styele>B type plate vibration isolators installation<\/h2>\n\t\t<h4>Screw 1 - for threaded blind holes a screw\n\t\t<\/br>is inserted into a bushing of a vibration isolator<\/h4><\/div>\n\t\n\t<img style=\"margin: 0 auto\" src=\"http:\/\/wibroinstal.stronazen.pl\/wp-content\/uploads\/2015\/03\/B-sruba-1.jpg\">\n            \n    <p>\n\t\t<table cellpadding=\"0\" cellspacing=\"0\" border=\"0\" class=\"zielona\" style=\"width: 100%;\">\t\n\t\t\t<tr>\n\t\t\t<td><img style=\"margin: 0 auto\" src=\"http:\/\/wibroinstal.stronazen.pl\/wp-content\/uploads\/2015\/03\/B-sruba-1_rys-1.jpg\" alt=\"gb\" border=\"0\"><\/td>\n\t\t\t<td><img style=\"margin: 0 auto\" src=\"http:\/\/wibroinstal.stronazen.pl\/wp-content\/uploads\/2015\/03\/B-sruba-1_rys-2.jpg\" alt=\"gb\" border=\"0\"><\/td>\n            <td><img style=\"margin: 0 auto\" src=\"http:\/\/wibroinstal.stronazen.pl\/wp-content\/uploads\/2015\/03\/B-sruba-1_rys-3.jpg\" alt=\"gb\" border=\"0\"><\/td>\n\t\t\t<\/tr>\n\t\t<\/table>\n\t<\/p>\n                 \n\t<p>\n\t<strong>Order of operations:<\/strong>\n\t\t\t<p><strong>1. lift a machine<\/strong><\/p>\n\t\t\t<p><strong>2. screw the mounting screws into the threaded holes in the base of a machine <\/strong><\/p>\n\t\t\t<p><strong>3. slide the vibration isolators under the cylindrical points of the mounting screws<\/strong><\/p>\n\t\t\t<p><strong>4. lower a machine inserting the cylindrical points of the mounting screws into the bushings of the vibration isolators<\/strong><\/p>\n\t\t\t<p><strong>5. level the machine by turning the mounting screw right \u2013 lifting, left \u2013 lowering, level evenly on all mounting screws<\/strong><\/p>\n\t\t\t<p><strong>6. secure the leveling of a machine by clamping a spring washer on the mounting screws using a locknut<\/strong><\/p>\n\t\t\t<p><strong>7. verify the leveling of a machine after ca 1 week of operation and correct the leveling if required.<\/strong><\/p>\n\t<\/p>\n\t<p><strong>A machine should be leveled at a minimal distance from the floor.<\/strong><\/p>\n<\/div>\n\n<div>\n\t<div style=\"text-align:center;\">\n\t\t<h4>Screw 2A - for unthreaded through holes a screw\n\t\t<br\/>is inserted into a bushing of a vibration isolator<\/h4>\n\t<\/div>\n\t<img style=\"margin: 0 auto\"src=\"http:\/\/wibroinstal.stronazen.pl\/wp-content\/uploads\/2015\/03\/B-sruba-2a.jpg\">\n            \n\t\t\t<p>\n\t\t\t  <table cellpadding=\"0\" cellspacing=\"0\" border=\"0\" class=\"zielona\" style=\"width: 100%;\">\n\t\n\t\t\t\t <tr>\n\t\t\t\t <td class=\"foto\"><img style=\"margin: 0 auto\" src=\"http:\/\/wibroinstal.stronazen.pl\/wp-content\/uploads\/2015\/03\/B-sruba-2a_rys-1.jpg\" alt=\"gb\" border=\"0\" \/><\/td>\n\t\t\t\t <td class=\"foto\"><img style=\"margin: 0 auto\" src=\"http:\/\/wibroinstal.stronazen.pl\/wp-content\/uploads\/2015\/03\/B-sruba-2a_rys-2.jpg\" alt=\"gb\" border=\"0\" \/><\/td>\n                 <td class=\"foto\"><img style=\"margin: 0 auto\" src=\"http:\/\/wibroinstal.stronazen.pl\/wp-content\/uploads\/2015\/03\/B-sruba-2a_rys-3.jpg\" alt=\"gb\" border=\"0\" \/><\/td>\n\t\t\t\t <\/tr>\n\t\t\t <\/table>\n\t\t\t <\/p>\n                 \n<p><strong>Order of operations:<\/strong>\n           <p><strong>1. lift a machine<\/strong><\/p>\n           <p><strong>2. slide the vibration isolators with inserted mounting screws under the holes in the base of a machine  <\/strong>\n<\/p>\n  <p><strong>3.lower a machine inserting the mounting screws into the holes in the base of the machine\n<\/strong>\n<\/p>\n  <p><strong>4. level a machine by turning the lower leveling nuts right \u2013 lifting, left \u2013 lowering, level evenly on all mounting screws \n<\/strong>\n<\/p>\n  <p><strong>5.secure the leveling of a machine by clamping a spring washer on the mounting screws using the upper locknut\n\n\n\n<\/p>\n<p><strong>6. verify the leveling of a machine after ca 1 week of operation and correct the leveling if required<\/strong>\n\n\n\n\n<\/p>\n<\/p>\n<p><strong>A machine should be leveled at a minimal distance from the floor.<\/strong><\/p>\n\n<\/div>\n\n<\/br>\n<div>\n\n<div style=\"text-align: center;\">\n\t\t<h4>Screw 2A - for threaded through holes a screw\n<br\/>is inserted into a bushing of a vibration isolator<\/h4><\/div>\n\n\n            \n              <p><table cellpadding=\"0\" cellspacing=\"0\" border=\"0\" class=\"zielona\" style=\"width: 100%;\">\n\t\n\t\t\t\t <tr><td class=\"foto\"><img margin: 0 auto src=\"http:\/\/wibroinstal.stronazen.pl\/wp-content\/uploads\/2015\/03\/B-sruba-2a_rys-1-1.jpg\" alt=\"gb\" border=\"0\" \/><\/td>\n\t\t\t\t <td class=\"foto\"><img margin: 0 auto src=\"http:\/\/wibroinstal.stronazen.pl\/wp-content\/uploads\/2015\/03\/B-sruba-2a_rys-2-2.jpg\" alt=\"gb\" border=\"0\" \/><\/td>\n                \n\t\t\t\t <\/tr><\/table><\/p>\n                 \n<p><strong>Order of operations:<\/strong>\n           <p><strong>1. lift a machine<\/strong><\/p>\n           <p><strong>2. screw the mounting screws into the threaded holes in the base of a machine<\/strong><\/p>\n\t\t<p><strong>3. slide the vibration isolators under the cylindrical points of the mounting screws<\/strong>\n<\/p>\n  <p><strong>4. lower a machine inserting the cylindrical points of the mounting screws into the bushings of the vibration isolators<\/strong>\n<\/p>\n  <p><strong>5. level the machine by turning the mounting screw right \u2013 lifting, left \u2013 lowering, level evenly on all mounting screws<\/strong>\n\n\n\n\n<\/p>\n<p><strong>6.secure the leveling of a machine by clamping a spring washer on the mounting screws using the upper locknut<\/strong>\n<\/p>\n<p><strong>7. verify the leveling of a machine after ca 1 week of operation and correct the leveling if required.\n<\/strong>\n\n<\/p>\n<\/ol><\/p>\n<p><strong>A machine should be leveled at a minimal distance from the floor.<\/strong><\/p>\n\n<\/div>\n<div>\n<div style=\"text-align: center;\">\n\t\t<h4>Screw 2B - for unthreaded through holes a screw\n<br\/>is inserted into a bushing of a vibration isolator<\/h4><\/div>\n\n<img style=\"margin: 0 auto\" src=\"http:\/\/wibroinstal.stronazen.pl\/wp-content\/uploads\/2015\/03\/B-sruba-2b.jpg\">\n            \n              <p><table cellpadding=\"0\" cellspacing=\"0\" border=\"0\" class=\"zielona\" style=\"width: 100%;\">\n\t\n\t\t\t\t <tr><td class=\"foto\"><img style=\"margin: 0 auto\" src=\"http:\/\/wibroinstal.stronazen.pl\/wp-content\/uploads\/2015\/03\/B-sruba-2b_rys-1.jpg\" alt=\"gb\" border=\"0\" \/><\/td>\n\t\t\t\t <td class=\"foto\"><img style=\"margin: 0 auto\" src=\"http:\/\/wibroinstal.stronazen.pl\/wp-content\/uploads\/2015\/03\/B-sruba-2b_rys-2.jpg\" alt=\"gb\" border=\"0\" \/><\/td>\n                 <td class=\"foto\"><img style=\"margin: 0 auto\" src=\"http:\/\/wibroinstal.stronazen.pl\/wp-content\/uploads\/2015\/03\/B-sruba-2b_rys-3.jpg\" alt=\"gb\" border=\"0\" \/><\/td>\n\t\t\t\t <\/tr><\/table><\/p>\n                 \n<p><strong>Order of operations:<\/strong>\n           <p><strong>1. lift a machine<\/strong><\/p>\n           <p><strong>2. slide the vibration isolators with tightly screwed in mounting screws under the holes in the base of a machine<\/strong><\/p>\n  <p><strong>3. lower a machine inserting the mounting screws into the holes in the base of the machine<\/strong><\/p>\n  <p><strong>4. level a machine by turning the lower leveling nuts right \u2013 lifting, left \u2013 lowering, level evenly on all mounting screws<\/strong>\n\n<\/p>\n  <p><strong>5. secure the leveling of a machine by clamping a spring washer on the mounting screws using the upper locknut<\/strong>\n\n\n<\/p>\n<p><strong>6. verify the leveling of a machine after ca 1 week of operation and correct the leveling if required.<strong>\n<\/p>\n<\/ol><\/p>\n<p><strong>A machine should be leveled at a minimal distance from the floor.<\/strong><\/p>\n\n<\/div>\n\n\n<div>\n\n<div style=\"text-align: center;\">\n\t\t<h4>Screw 2B- for threaded through holes a screw\n<br\/> is inserted into a bushing of a vibration isolator<\/h4><\/div>\n            \n              <p><table cellpadding=\"0\" cellspacing=\"0\" border=\"0\" class=\"zielona\" style=\"width: 100%;\">\n\t\n\t\t\t\t <tr><td class=\"foto\"><img style=\"margin: 0 auto\" src=\"http:\/\/wibroinstal.stronazen.pl\/wp-content\/uploads\/2015\/03\/B-sruba-2b_rys-1-1.jpg\" alt=\"gb\" border=\"0\" \/><\/td>\n\t\t\t\t <td class=\"foto\"><img style=\"margin: 0 auto\" src=\"http:\/\/wibroinstal.stronazen.pl\/wp-content\/uploads\/2015\/03\/B-sruba-2b_rys-1-2.jpg\" alt=\"gb\" border=\"0\" \/><\/td>\n                 \t <td class=\"foto\"><img style=\"margin: 0 auto\" src=\"http:\/\/wibroinstal.stronazen.pl\/wp-content\/uploads\/2015\/03\/B-sruba-2b_rys-1-3.jpg\" alt=\"gb\" border=\"0\" \/><\/td>\n                \n\t\t\t\t <\/tr><\/table><\/p>\n                 \n<p><strong>Order of operations:<\/strong>\n           <p><strong>1. screw the mounting screws tightly into the threaded bushings of the vibration isolator<\/strong><\/p>\n           <p><strong>2. lift a machine  <\/strong> \n<\/p>\n  <p><strong>3. screw  the vibration isolators tightly into the threaded holes in the base of a machine<\/strong>\n<\/p>\n  <p><strong>4. lower the machine with the screwed in vibration isolators<\/strong>\n<\/p>\n  <p><strong>5. secure the screwing of a machine with the vibration isolators by clamping a spring washer on the mounting screws using a locknut<\/strong>\n<\/p>\n<\/p>\n<\/div>\n<div style=\"text-align: center;\">\n\t\t<h4>Socket \u2013 for fixing a cotter:<\/h4><\/div>\n\n            \n              <p><table cellpadding=\"0\" cellspacing=\"0\" border=\"0\" class=\"zielona\" style=\"width: 100%;\">\n\t\n\t\t\t\t <tr><td class=\"foto\"><img style=\"margin: 0 auto\" src=\"http:\/\/wibroinstal.stronazen.pl\/wp-content\/uploads\/2017\/01\/B-gniazdo_rys-1.jpg\" alt=\"gb\" border=\"0\" \/><\/td>\n\t\t\t\t <td class=\"foto\"><img style=\"margin: 0 auto\" src=\"http:\/\/wibroinstal.stronazen.pl\/wp-content\/uploads\/2017\/01\/B-gniazdo_rys-2.jpg\" alt=\"gb\" border=\"0\" \/><\/td>\n              \n\t\t\t\t <\/tr><\/table><\/p>\n                 \n<p><strong>Order of operations:<\/strong>\n           <p><strong>1. lift a machine<\/strong><\/p>\n           <p><strong>2. screw the cotters into the threaded holes in the base of a machine<\/strong>\n\n<\/p>\n  <p><strong>3. slide the vibration isolators under the cotters<\/strong>\n<\/p>\n  <p><strong>4. lower a machine inserting the cotters into the bushings of the vibration isolators<\/strong>\n\n<\/p>\n  <p><strong>5. level a machine by turning the cotters left \u2013 lifting, right \u2013 lowering, level evenly on all cotters<\/strong>\n\n\n\n<\/p>\n<p><strong>6. secure the leveling of a machine by clamping a spring washer on the cotters using a locknut<\/strong>\n\n\n\n\n<\/p>\n\n<p><strong>7.verify the leveling of a machine after ca 1 week of operation and correct the leveling if required.<\/strong>\n\n\n\n\n\n<\/p>\n<\/ol><\/p>\n<p><strong>A machine should be leveled at a minimal distance from the floor.<\/strong><\/p>\n\n<\/div>\n\n\n<div>\n\n<\/br>\n<div style=\"text-align: center;\">\n\t\t<h4>Socket \u2013 for fixing a threaded mandrel<\/h4><\/div>\n            \n              <p><table cellpadding=\"0\" cellspacing=\"0\" border=\"0\" class=\"zielona\" style=\"width: 100%;\">\n\t\n\t\t\t\t <tr><td class=\"foto\"><img style=\"margin: 0 auto\" src=\"http:\/\/wibroinstal.stronazen.pl\/wp-content\/uploads\/2017\/01\/B-gniazdo_rys-1-1.jpg\" alt=\"gb\" border=\"0\" \/><\/td>\n\t\t\t\t <td class=\"foto\"><img style=\"margin: 0 auto\" src=\"http:\/\/wibroinstal.stronazen.pl\/wp-content\/uploads\/2017\/01\/B-gniazdo_rys-1-2.jpg\" alt=\"gb\" border=\"0\" \/><\/td>\n           \n                \n\t\t\t\t <\/tr><\/table><\/p>\n                 \n<p><strong>Order of operations:<\/strong>\n           <p><strong>1. lift a machine<\/strong><\/p>\n           <p><strong>2. screw the threaded mandrels into the threaded holes in the base of a machine<\/strong>\n<\/p>\n  <p><strong>3. slide the vibration isolators under the cylindrical points of the threaded mandrels<\/strong>\n\n\n<\/p>\n  <p><strong>4. lower a machine inserting the cylindrical points of the threaded mandrels into the bushings of the vibration isolators<\/strong>\n\n\n<\/p>\n  <p><strong>5. level a machine by turning the threaded mandrels left \u2013 lifting, right \u2013 lowering, level evenly on all threaded mandrels<\/strong>\n\n\n\n\n<\/p>\n  <p><strong>6. secure the leveling of a machine by clamping a spring washer on the threaded mandrels using a locknut<\/strong>\n\n\n\n\n\n<\/p>\n  <p><strong>7. verify the leveling of a machine after ca 1 week of operation and correct the leveling if required.<\/strong>\n\n\n\n<\/p>\n\n\n\n\n\n\n<\/p>\n<p><strong>A machine should be leveled at a minimal distance from the floor.<\/strong><\/p>\n\t\t<\/div> \n\n\t\t<\/div> \n\t<\/div> \n\t\t<\/div> \n\t<\/div> \n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"B type plate vibration isolators installation Screw 1 - for threaded blind holes a screw is inserted into a bushing of a vibration isolator Order of operations: 1. lift a...","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"http:\/\/wibroinstal.pl\/en\/wp-json\/wp\/v2\/pages\/974"}],"collection":[{"href":"http:\/\/wibroinstal.pl\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/wibroinstal.pl\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/wibroinstal.pl\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/wibroinstal.pl\/en\/wp-json\/wp\/v2\/comments?post=974"}],"version-history":[{"count":4,"href":"http:\/\/wibroinstal.pl\/en\/wp-json\/wp\/v2\/pages\/974\/revisions"}],"predecessor-version":[{"id":993,"href":"http:\/\/wibroinstal.pl\/en\/wp-json\/wp\/v2\/pages\/974\/revisions\/993"}],"wp:attachment":[{"href":"http:\/\/wibroinstal.pl\/en\/wp-json\/wp\/v2\/media?parent=974"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}